low voltage

Hotline

Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter

description:Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis mass flowmeter for configured-instrument replacement, nameplate matching, technical review and industrial RFQ support....
BASIC INFO

Configuration and RFQ Guide for Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter

Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter is a configured member of the Endress+Hauser Proline Promass F 300 family. The complete extended order code should be retained for quotation and replacement review because process connection, materials, electronics, approvals, calibration and additional options can vary within the family.

Product identity and configuration scope

Manufacturer Endress+Hauser
Product family Proline Promass F 300
Product root 8F3B
Extended order code 8F3B08-BDDBAAAFABSADOSAA2+AADC
Measurement principle Coriolis
Measured variables Mass flow, volume flow, density and temperature, configuration dependent
Transmitter format Compact Proline 300 platform
Inquiry purpose Configured replacement, MRO spare, project supply or nameplate matching

The 8F3B product root identifies Promass F 300. The characters after the product root form the configured order code. HKXY therefore recommends comparing every character with the installed nameplate and purchase record instead of selecting a replacement from the short family name alone.

 

Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter supplied product image

Supplied product image for model and nameplate review. Confirm the delivered extended order code, serial number, process connection and approval markings against the purchase requirement.

 

Promass F 300 family performance context

Endress+Hauser describes Promass F 300 as a Coriolis flowmeter designed for high measurement performance with liquids and gases under demanding process conditions. The measuring principle is independent of fluid viscosity and density, and the device supports multivariable measurement so one measuring point can provide flow, density and temperature data.

Mass-flow error, liquid ±0.10% standard; ±0.05% option at family level
Volume-flow error, liquid ±0.10% at family level
Mass-flow error, gas ±0.25% at family level
Density error, liquid ±0.0005 g/cm³ at family level
Family measuring range Up to 2,200,000 kg/h, depending on nominal size and configuration
Nominal-size range DN 8 to DN 250 across the Promass F 300 family
Medium-temperature scope Multiple standard, extended and high-temperature versions are available
Installation characteristic No straight inlet or outlet run is normally required by the measuring principle
Diagnostics Heartbeat Technology and device diagnostics, depending on selected configuration

These values describe the product family and are not a decoded certificate for this exact extended order code. The final limits for 8F3B08-BDDBAAAFABSADOSAA2+AADC must be taken from its nameplate, calibration documents, ordered options and the applicable Endress+Hauser documentation.
 

Endress Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B08-BDDBAAAFABSDDOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B15-BDDBAAAFABSAD8SAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B15-BDDBAAAFABSAD8SAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B15-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B15-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B15-BDDBAAAFABSDDOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B25-BDDBAAAFABSAD8SAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B80-BDDBAAAFABSAD8SAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B25-BDDBAAAFABSDDOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B80-BCDMAEBOABSADOSAA2+AADCDD Promass F 300 Coriolis Mass Flowmeter
Endress Hauser 8F3B50-BCDMAEBOABSADOSAA2+AADCDD Promass F 300 Coriolis Mass Flowmeter
 

Typical applications and buyer considerations

Promass F 300 instruments are considered for chemical processing, oil and gas, food and beverage, life-science and other process applications that need stable mass-flow and density measurement. Suitability still depends on wetted materials, pressure rating, process connection, temperature, hazardous-area approval, hygiene requirements and communication interface.

For an existing installation, Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter should be reviewed together with the piping specification and control-system I/O. A visually similar Promass F 300 can have a different transmitter output, housing, connection, calibration or approval and may not be a drop-in replacement.

Replacement and RFQ checklist

  1. Send clear front, side and nameplate photographs, including the complete extended order code.
  2. State the required quantity, condition, destination country and requested delivery date.
  3. Confirm process medium, expected flow range, pressure and temperature.
  4. Record nominal size, process connection, wetted material and pressure class.
  5. Confirm power supply, output or communication protocol and any hazardous-area approval.
  6. Include calibration, material, inspection and traceability documents required by the project.

Providing these details helps HKXY review the exact configuration, reduce quotation ambiguity and identify whether accessories, documentation or a current equivalent need to be included.

Frequently asked questions

Is 8F3B08 enough to select a replacement?

No. It identifies the product family and size code context, but the complete extended order code and nameplate data are needed to check the configured instrument.

Can Promass F 300 measure liquids and gases?

The Promass F 300 family is designed for liquid and gas measurement. The application range and accuracy for a supplied unit depend on its selected size, calibration and process conditions.

What should be included with an urgent inquiry?

Send the full code 8F3B08-BDDBAAAFABSADOSAA2+AADC, quantity, readable nameplate photos, process conditions, destination and deadline. This is more reliable than sending only the family name.

Manufacturer references

Endress+Hauser Proline Promass F 300 product page and Promass F 300 Technical Information. The latest manufacturer documents and the delivered device records take precedence over this sourcing summary.

 

 

 

Pre:Endress hauser TH52 US style thermocouple sensor for sale. Next:None